MP2519 RADIO MODEM
Cost-Effective Wireless Solutions |
|
|
|
|
|
|
|
Radio modems provide a simple wireless link with the ability to send any message protocol at any data rate up to the maximum quoted. They provide a simple means of passing RS232 data streams with no message overhead in the form of extra addressing or error-checking codes.
The MP2519 modem pcb is designed to operate with Magenta's synthesized Radio Modules. It is a non-intelligent device to provide a serial radio data link primarily for incorporating into OEM's systems.
Serial data supplied to the transmitter input is reproduced at the distant receiver's output. Only when operating near the limit of maximum range will the received output be prone to data corruptions.
An I2C bus is used to control all modem functions as well as the transceiver functions such as frequency selection, transmitter-receiver switching and power control.
When the transmitter is switched off at the end of a message, a short burst of noise may occur before the receiver's mute operates. This noise should be ignored by the system connected to the receiver.
The user may need to provide error checking and/or addressing to each mesage if the application requires guaranteed data integrity.
Options are available for RS232 or TTL data levels. The transceiver must be ordered separately.
|
Technical Details |
||
|
General |
||
|
TX-RX Changeover |
<6ms |
|
|
TX and RX Risetime |
<6ms |
|
|
Data Rate |
1200 baud (2400 or 4800 optional-state with order) |
|
|
Supply Voltage |
5Vdc |
|
|
Dimensions |
Fits on top of radio module-adds 7mm to height |
|
|
Operating Temperature |
-30 to +60° C |
|
|
Humidity |
95% RH, non-condensing |
|
|
Current Consumption |
5mA excluding radio |
|
Technical Details |
||
|
Connections |
||
|
1 |
+V |
5V Positive supply |
|
2 |
SCL |
I2C clock |
|
3 |
TXD |
TX data input, RS232 levels |
|
4 |
0V |
Ground, negative supply |
|
5 |
RXD |
RX data output, RS232 levels |
|
6 |
/CD |
RX carrier detect, TTL active low |
|
7 |
SDA |
I2C data |
|
8 |
- |
No pin (for connector polarity) |
|
9 |
RSSI |
Received Signal Strength Indicator |
|
10 |
Spare |
|
|
Coaxial MCX |
50 ohm antenna connection (connect direct to transceiver) |